Characteristics:

 

4000 digital LCD screen, reading more clear

 

Automatic shutdown with low battery power and display capabilities, we can extend the battery life cycle, users can also timely to remind the replacement of low-power batteries.

 

Maintain the function of numerical data can be stored, for the operator to accurately read the measurement.

 

When the DC current measurement function cleared

 

 

DC current measurement
Range: 3, 20 A, 40A, 200A
Basic accuracy:  (2.5% + 3d)
Resolution: 10mA
Note: Before measuring DC current test to ensure that no form T connected with the instrument.
AC current measurement
Range: 3, 20 A, 40A, 200A
Basic accuracy:  (3.0% + 4d)
The maximum resolution: 10mA
Note: AC current measurement before the test to ensure that the table T does not connect with the instrument.
DC voltage measurement
Range: 5, 400 mV, 4V, 40V, 400V, 600V
Basic accuracy:  (0.8% + 2d)
Resolution: 0.1 mV
AC voltage measurement
Range: 4, 4V, 40V, 400V, 600V
Basic accuracy:  (1.5% + 3d)
Resolution: 0.1 mV
Resistance measurement
The largest measuring resistance of 40 M Ω
Basic accuracy:  (1.2% + 4d)
Resolution: 0.01 M Ω
Capacitance measurement
The largest measuring capacitance to 200.0 uF
Basic accuracy:  (3.5% + 5d)
Resolution: 0.1 μ F
Frequency Measurement
The largest measuring frequency of 9.999 MHz, duty cycle of 0.1% to 99.9%
Basic accuracy:  (0.8% + 3d)
Resolution: 0.01 Hz
Diodes and short-circuit test
Diode test, the test current: 0.3 mA typical, open circuit voltage: 1.5 V DC typical
Short-circuit test, <30 Ω at the beep, the current test <0.3 mA
Numerical maintain functional
Press the button to maintain the numerical value locked. When the numerical maintain functional activities in the state will be displayed on the screen reading and "HOLD". Numerical again press the button to maintain cancel this feature.
Cleared function
Automatically cleared keys to DC current measurement, 400 mV DC voltage measurement, 4 V AC voltage measurement, capacitance measurement.

 

 

 Specifications 

 

 

Specifications: 

 

DC: 

 

Measuring range

 

Resolution

 

Accuracy rate (% of reading)

 

40A

 

0-20A

 

10mA

 

3.0%+6dgts

 

20A-40A

 

10mA

 

5.0%+6dgts

 

200A

 

100mA

 

3.5%+3dgts

 

Current exchange: 

 

Measuring range

 

Resolution

 

Accuracy rate (% of reading)

 

50~60Hz

 

60~100Hz

 

100~400Hz

 

400~1000Hz

 

0-20A

 

10mA

 

3%+4dgts

 

3%+7dgts

 

3%+10dgts

 

3%+30dgts

 

20-40A

 

10mA

 

5%+4dgts

 

5%+7dgts

 

5%+10dgts

 

5%+30dgts

 

200A

 

100mA

 

3.5%+4dgts

 

3.5%+7dgts

 

3.5%+10dgts

 

3.5%+30dgts

 

DC voltage (automatic measurement) 

 


Measuring range

 

Resolution

 

Accuracy rate (% of reading)

 

400.0mV

 

0.1mV

 

0.8% of rdg+2 dgts

 

4.000V

 

1mV

 

1.0% of rdg+2 dgts

 

40.00V

 

10mV

 

400.0V

 

100mV

 

600V

 

1V

 

1.5% of rdg+2 dgts

 

AC voltage (automatic measurement) 

 


Measuring range

 

Resolution

 

Accuracy rate (% of reading)

 

4.000V

 

1mV

 

1.5% of rdg+3 dgts

 

40.00V

 

10mV

 

400.0V

 

100mV

 

600V

 

1V

 

2.0% of rdg+4 dgts

 

Resistance (automatic measurement)

 


Measuring range

 

Resolution

 

Accuracy rate (% of reading)

 

Range

 

Resolution

 

Accuracy

 

 

400.0Ω

 

0.1Ω

 

1.2% of rdg+4 dgts

 

 

4.000kΩ

 

 

1.2% of rdg+2 dgts

 

 

40.00kΩ

 

10Ω

 

 

400.0kΩ

 

100Ω

 

 

4.000MΩ

 

1kΩ

 

 

40.00MΩ

 

10kΩ

 

2.0% of rdg+3 dgts

 

 

Capacitance (automatic measurement)

 



Measuring range

 

Resolution

 

Accuracy rate (% of reading)

 


  • 0 Units in Stock