Product features:
1. Optical measurement of the distance between high and target objects than (D: S = 16:1), not for measuring and around the goal.
2. Temperature wide range of -50 ~ 900℃ (-58 ~ 1652℉)
3. Unique new chassis design
4. Built-in laser sight and can quickly and accurately target
5. Numerical automatically maintain, for the operator to accurately read the measurement
6. Emissivity adjustment from 0.10 to 1.0, according to the need to choose a suitable launch rate
7.MAX, MIN, DIF, AVG temperature display
8. LCD display with backlighting, reading more clear
9. Automatically selected range, a resolution of 0.1℃ (0.1℉)
10. High and low temperature alarm settings Switch settings: ① ℃ /℉ conversion: ℃ and℉ button to select single-temperature (℃ /℉)
② on / off lock (LOCK): to be locked so that it remains measurement instruments, please Central Xuanniu LOCK ON / OFF sliding to the right ON.
③ alarm settings (SET ALARM): To open the alarm settings, I should be grateful if the following Xuanniu sliding to the right SET ALARM ON.
To set the alarm level high, low and fired warning of the value of, first of all through the promotion of the trigger or press the MODE button activated screen, then press the MODE button until the appropriate code in the lower left corner of the screen, press the button and the next Button to adjust to the desired value.
With the precision of measuring temperature
| To ensure accuracy of the operating environment temperature: 23 to 25℃ (73 to 77℉) |
| -50℃ ~ -20℃ (-58℉ to 68℉) | 5℃/9℉ |
| -20℃ ~ 200℃ (68℉ to 392℉) | 1.5% of reading +2.0℃/?.6℉ |
| 201℃ ~ 538℃ (393℉ to 1000.4℉) | 2.0% of reading +2℃(?.6℉F) |
| 539℃ ~ 900℃ (1000.4℉to 1652℉) | 3.0% of reading +5℃(?℉) |
Specifications
| Resolution | 2000℃ for less than 0.1℃ /℉: more than 2000℃ for 1℃ /℉ |
| Basic accuracy | 1.5% |
| Temperature range | -50℃~1300℃(-58oF~2372℉) |
| Optical ratio | 50:1 |
| Reaction time | Less than one second |
| Spectral Response | 8~14um |
| Emissivity | Launch rate from 0.1 to 1.0 adjustable |
| Beyond the range tips | LCD will show "-0L", "0L" |
| Polar show | Auto (cathode not shown); (-) indicates that negative |
| Two of the laser | Output <1 mw, 630 ~ 670nm Class 2 (II) laser products |
| Storage temperature | ?0 ~60℃ (14 ~140℉) |
| Operating temperature | 0~50℃(32~ 122℉) |
| Relative Humidity | 10% ~ 90% RH (operation), <80% RH (storage) |
| Power | 9V batteries, NEDA 1604A or IEC 6LR61, or other specifications with battery |
| Weight | 290 grams |
| Size | 120?20?6mm |
| Safety design standards | CE in line with European safety norms |