DT-362 4000-exchange clamp-table


Call for Price


Characteristics:

 

4000 digital LCD screen, and a backlight, reading more clear

 

Automatic shutdown with low battery power and display capabilities, we can extend the battery life cycle, users can also timely to remind the replacement of low-power batteries.

 

Data maintained function, for the operator to accurately read the measurement.

 

Non-contact AC voltage detection, the relative functions cleared

 

 

AC current measurement
Range: 2, 40A, 400A,
Basic accuracy:  (2.5% + 4d)
DC voltage measurement
Range: 5, 400 mV, 4V, 40V, 400V, 600V
Basic accuracy:  (0.5% + 1d)
AC voltage measurement
Range: 4, 4 V, 40V, 400V, 600V
Basic accuracy:  (1.5% + 2d)
Resistance measurement
The largest measuring resistance of 40 M Ω;
Short-circuit test, <150 Ω at the beep
Basic accuracy:  (3.0% + 5d)
Temperature measurement
The largest measuring frequency of 1000
/ 1832 F
Basic accuracy:  (3.0% + 3d)
Capacitance measurement
The largest measuring capacitance to 100 μ F
Basic accuracy:  (2.5% + 5d)
Frequency Measurement
The largest measuring frequency of 10 MHz,
Basic accuracy:  (1.2% + 2d)
Diodes and short-circuit test
Diode test, the test current 0.3 mA typical; open circuit voltage 1.5 V DC typical.
Short-circuit test, <150 Ω at the beep; test current <0.5mA,
Numerical maintain functional
Press the button to maintain the numerical value locked. Numerical maintain the function keys in the table on the left side. When the numerical maintain functional activities in the state will be displayed on the screen HOLD. Numerical again press the button to maintain cancel this feature.
Note: When the backlight is opened to maintain functional data is in progress. Numerical again press the button to withdraw from maintaining this feature
Backlight used in the case of inadequate lighting to illuminate screens. Press the button one second to open backlight, once again press this button one second to turn off the backlight.
Cleared function
The key to capacitance cleared and offset adjustment
Range keys
This instrument is an automated range. Press the button RANGE switch to manual range. The range button you can gradually transferred to the range of holding down
RANGE key two seconds back to Automatic.
 

 

 

 Specifications 

 

 

Function

 

Measurement range and resolution

 

Accuracy rate (% of reading)

 

AC current
(50/60Hz)

 

40.00AAC

 

 (2.5 % + 8 digits)

 

400.0 AAC

 

 (2.8 % + 8 digits)

 

DC voltage

 

400.0 mVDC

 

 (0.8% + 2 digits)

 

4.000 VDC

 

 (1.5% + 2digits)

 

40.00 VDC

 

400.0 VDC

 

600.0 VDC

 

 (2 % + 2 digits)

 

AC voltage
(50-400Hz)

 

4.000 VAC

 

 (1.8% + 8 digits)

 

40.00 VAC

 

400.0 VAC

 

600.0 VAC

 

 (2.5% + 8 digits)

 

Resistance

 

400.0 Ω

 

 (1.0% + 4 digits)

 

4.000KΩ

 

 (1.5% + 2 digits)

 

40.00KΩ

 

400.0KΩ

 

4.000MΩ

 

 (2.5% + 3 digits)

 

40.00MΩ

 

 (3.5% + 5 digits)

 

Capacitance

 

40.00nF

 

(4.0% reading + 20 digits)

 

400.0nF

 

(3% reading + 5 digits)

 

4.000μF

 

40.00μF

 

100.0μF

 

(4.0% reading + 10 digits)

 

Frequency
Sensitivity: 15 Vrms

 

10-10kHz

 

(1.5% reading + 2 digits)

 

Temperature
(K-)
(Not including the probe precise rate)

 

-20.0 to 760.0 

 

 (3%rdg+5)

 

-4.0 to1400.0 F

 

 (3%rdg+9 F)

 